DS620F1
17
CS4384
SWITCHING CHARACTERISTICS - CONTROL PORT - SPI FORMAT
(Inputs: Logic 0 = GND, Logic 1 = VLC, CL =30pF)
Notes:
18. tspi only needed before first falling edge of CS after RST rising edge. tspi = 0 at all other times.
19. Data must be held for sufficient time to bridge the transition time of CCLK.
20. For FSCK < 1 MHz.
Parameter
Symbol
Min
Max
Unit
CCLK Clock Frequency
fsclk
-6
MHz
RST Rising Edge to CS Falling
tsrs
500
-
ns
CCLK Edge to CS Falling
tspi
500
-
ns
CS High Time Between Transmissions
tcsh
1.0
-
s
CS Falling to CCLK Edge
tcss
20
-
ns
CCLK Low Time
tscl
66
-
ns
CCLK High Time
tsch
66
-
ns
CDIN to CCLK Rising Setup Time
tdsu
40
-
ns
CCLK Rising to DATA Hold Time
tdh
15
-
ns
Rise Time of CCLK and CDIN
tr2
-100
ns
Fall Time of CCLK and CDIN
tf2
-100
ns
t r2
t f2
t dsu t dh
t sch
t scl
CS
CC L K
CD IN
t css
t csh
t spi
t srs
RST
Figure 6. Control Port Timing - SPI Format